The HBLG-300 square cross flow GFRP cooling tower distinguishes itself through a modular drift eliminator system that achieves <0.001% water loss, directly addressing water-scarce regional permits. Our factory-direct model eliminates intermediary markups while offering flexible OEM branding on casing panels and fan stacks – a feature rarely available from trading houses. We pair each shipment with a digital installation manual, 3D explosion drawings, and remote vibration monitoring guidance, reducing site assembly errors by 40%. Backed by 12 years of exporting to Southeast Asia, Middle East, and Latin America, we provide seawater-resistant coating options and tropicalized motor variants, transforming a standard cooling tower into a site-specific asset for your EPC project timeline.
Hebei Fortis Technology Co., Ltd Produktbroschüre
Product Advantages
Gravity-Fed Nozzle-Free Distribution – Minimal Fouling, Maximum Uptime
Unlike forced-draft or counterflow towers that rely on pressurized spray nozzles, the HBLG-300 employs a gravity-fed hot water basin with metering orifices over the fill media. This design inherently resists clogging from suspended solids, algae, and high-TDS recirculated water. For industries like steel rolling, biomass power, or chemical batch processing where water quality fluctuates, this translates to fewer shutdowns for cleaning, lower manual intervention costs, and sustained thermal performance across years of continuous operation.
True Square Cross-Flow Architecture – Serviceability Without Shutdown
The square planform enables full frontal access to the fill pack and drift eliminators on two opposite sides. Maintenance crews can inspect, hose-clean, or replace fill sections while the tower remains online – a critical operational advantage for baseload plants that cannot afford scheduled outages. The straight-through airflow path also reduces static pressure drop compared to complex redirective designs, allowing you to run the fan motor at lower amp draw for the same nominal heat rejection duty.
CTI-Verified Thermal Performance with Site-Specific Adjustability
Every HBLG-300 unit is thermally rated per CTI Standard-201, but we go beyond nameplate data. As the factory exporter, we adjust fill depth, louver angle, and basin retention time based on your local wet-bulb temperature, elevation, and seasonal variance. We provide project-specific performance curves (not generic catalog pages), so your EPC team can precisely size pumps and piping without overdesigning – directly lowering your capital expenditure while guaranteeing outlet temperature within ±0.5°C of the design point.
Parameter Specifications
|
|
||||||||||
|
Product |
Square Cross Flow Cooling Tower |
|||||||||
|
Model |
τ=28℃ |
Main Dimensions (mm) |
Air Volume m³/h |
Fan Diameter (mm) |
Motor Installed Capacity (kw) |
Weight (t) |
τ=28℃ |
Noise at standard point |
||
|
Total Height |
Length× |
self-weight |
operating weight |
|||||||
|
AHBLD/HBLD-300 |
300 |
4514 |
7250× 3810 |
167000 |
3400 |
7.5 |
5.85 |
13.38 |
/ |
59.0 |
|
AHBLD/HBLD-500 |
500 |
5230 |
8033× 4650 |
260000 |
4200 |
11.0 |
9.2 |
17.24 |
/ |
61.5 |
|
AHBLD/HBLD-700 |
700 |
5319 |
8930× 6640 |
370000 |
5000 |
18.5 |
12.95 |
26.05 |
/ |
62.6 |
|
AHBLCD/HBLCD-300 |
300 |
6230 |
10650× 3810 |
167000 |
3400 |
7.5 |
7.05 |
14.18 |
/ |
52.5 |
|
AHBLCD/HBLCD-500 |
500 |
7030 |
11640× 4650 |
260000 |
4200 |
11.0 |
10.8 |
18.84 |
/ |
53.7 |
|
AHBLCD/HBLCD-700 |
700 |
7180 |
12540× 6640 |
370000 |
5000 |
18.5 |
14.75 |
26.81 |
/ |
54.5 |
|
AHBLG/HBLG-300 |
/ |
4514 |
7250× 3810 |
200000 |
3400 |
11.0 |
6.13 |
13.66 |
300 |
64.5 |
|
AHBLG/HBLG-500 |
/ |
5230 |
8033× 4650 |
320000 |
4200 |
18.5 |
9.42 |
17.46 |
500 |
65.0 |
|
AHBLG/HBLG-700 |
/ |
5319 |
8930× 6640 |
450000 |
5000 |
30.0 |
13.19 |
26.29 |
700 |
66.0 |
|
The standard point noise is measured at a distance equal to the equivalent diameter of the air inlet window or its shield equivalent diameter, and 1.5 meters above the ground. The equivalent diameter Dₘis calculated by the formula: Dₘ= 1.13×Length×Width |
||||||||||
|
Features |
The FRP cooling tower serves not only as a temperature regulator but also delivers an efficient, durable, and maintenance-free solution with optimized lifecycle costs. By harnessing the unique properties of FRP materials, it fundamentally addresses the critical challenges of corrosion and lifespan limitations in harsh operating environments, making it the go-to choice for cooling systems in modern industrial and commercial facilities. |
|||||||||
|
Application
|
Central air conditioning system: refrigeration station for commercial buildings, hotels and hospitals. |
|||||||||
|
Industrial refrigeration: process cooling for food processing, chemical, pharmaceutical and plastic industries. |
||||||||||
|
Power industry: auxiliary cooling system for thermal power plant and nuclear power plant. |
||||||||||
|
Manufacturing industry: circulating water cooling for metallurgical and mechanical processing plants. |
||||||||||
|
Data center: Provides cooling water for server rooms. |
||||||||||
|
Payment |
T/T, Western Union. |
|||||||||
|
Service |
Customize and design the size and style according to requirements |
|||||||||
Kontaktieren Sie uns umgehend, um die Anforderungen Ihres Produktprojekts zu besprechen.
Navigation
Navigation
Kontaktieren Sie uns
Tel.: +86 189 3266 2725
E-Mail: sale@hbfortis.com
Hinzufügen.: Nr. 8-1, Zhenxing Street, Stadt Matun, Kreis Zaoqiang, Stadt Hengshui, Provinz Hebei
Nehmen Sie Kontakt auf
Nehmen Sie Kontakt auf